Siemens SINUMERIK 808D Parameter Manual page 364

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

NC setting data
Description:
A minimum spindle speed limit below which the spindle must not fall is entered in
SPIND_MIN_VELO_G25. The NCK limits the set spindle speed to this value if it is too
low.
The spindle speed may only fall below the minimum as a result of:
Spindle offset 0%
M5
S0
NC/PLC interface signal DB380x DBX4.3 (Spindle stop)
NC/PLC interface signal DB380x DBX2.1 (Servo enable)
NC/PLC interface signal DB3300 DBX3.7 (Channel status: Reset)
NC/PLC interface signal DB380x DBX2.2 (Delete distance-to-go/Spindle reset)
NC/PLC interface signal DB380x DBX2002.5 (Oscillation speed)
Cancel S value
SD irrelevant to ......
other spindle modes used in open-loop control mode (SPOS, M19, SPOSA)
Related to:
43220
SPIND_MAX_VELO_G26
rev/min
Programmable upper spindle speed limitation G26
-
-
-
Description:
A maximum spindle speed is entered in SD43220 $SA_SPIND_MAX_VELO_G26, which the
spindle must not exceed. The NCK limits an excessive spindle speed setpoint to this
value.
SD irrelevant for ......
all spindle modes except open-loop control mode.
Special cases, errors, ......
The value in SD43210 $SA_SPIND_MIN_VELO_G26 can be altered by means of:
G26 S.... in the part program
Operator commands via HMI
The value in SD43210 $SA_SPIND_MIN_VELO_G26 is retained after a reset or Power Off.
Related to ....
SD43210 $SA_SPIND_MIN_VELO_G25 (programmed spindle speed limit G25)
SD43230 $SA_SPIND_MAX_VELO_LIMS (programmed spindle speed limit G96/961)
MD10709 $MN_PROG_SD_POWERON_INIT_TAB
MD10710 $MN_PROG_SD_RESET_SAVE_TAB
43230
SPIND_MAX_VELO_LIMS
rev/min
Spindle speed limitation with G96
-
-
-
Description:
Limits the spindle speed with G96, G961, G97 to the stated maximum value [degrees/
second]. This setting data can be written from the block with LIMS.
Note:
MD 10710 $MN_PROG_SD_RESET_SAVE_TAB can be set so that the value written by the part
program is transferred into the active file system on reset (that is the value is
retained after reset).
Related to ....
364
MD10709 $MN_PROG_SD_POWERON_INIT_TAB
MD10710 $MN_PROG_SD_RESET_SAVE_TAB
1000.0
100.0
SD43210 $SA_SPIND_MIN_VELO_G25 (programmed spindle speed limit G25)
-
DOUBLE
0.0
-
-
DOUBLE
0.0
-
S1
Immediately
7/7
U
S1, Z1
Immediately
7/7
U
Parameter Manual
List Manual, 01/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced

Table of Contents