Siemens SINUMERIK 808D Parameter Manual page 288

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Machine data
3.4 Axis-specific machine data
See MD35110 $MA_GEAR_STEP_MAX_VELO for more information.
Note:
Programming a spindle speed which undershoots the lowest speed of the first gear
stage MD35120 $MA_GEAR_STEP_MIN_VELO[1] triggers a switch to the first gear stage.
Not relevant for:
Programming of speed 0 (S0) if MD35120 $MA_GEAR_STEP_MIN_VELO[1] > 0
Related to:
MD35110 $MA_GEAR_STEP_MAX_VELO (maximum speed for automatic gear stage selection M40)
MD35090 $MA_NUM_GEAR_STEPS (number of gear stages)
MD35010 $MA_GEAR_STEP_CHANGE_ENABLE (gear stage change is possible)
MD35130 $MA_GEAR_STEP_MAX_VELO_LIMIT (maximum speed of the gear stage with speed
control)
MD35135 $MA_GEAR_STEP_PC_MAX_VELO_LIMIT (maximum speed of the gear stage with position
control)
MD35140 $MA_GEAR_STEP_MIN_VELO_LIMIT (min. speed of the gear stage)
35122
GEAR_STEP_MIN_VELO2
rev/min
2nd data set: Minimum speed for gear stage change
CTEQ
-
6
Description:
The minimum speed (lower switching threshold) of the gear stage for automatic gear
stage change M40 G331 S.. is set in GEAR_STEP_MIN_VELO2 for interpolatory tapping
G331, G332. The speed ranges of the gear stages must be defined so that there are no
gaps between them or they can overlap.
The 2nd gear stage data block for tapping with G331/G332 is activated with MD35010
$MA_GEAR_STEP_CHANGE_ENABLE bit 5 for the master spindle.
Related to:
MD35112 $MA_GEAR_STEP_MAX_VELO2 (maximum speed for 2nd data block gear stage change)
MD35092 $MA_NUM_GEAR_STEPS2 (number of gear stages 2nd gear stage data block)
MD35010 $MA_GEAR_STEP_CHANGE_ENABLE (gear stage change, 2nd data block is possible)
MD35130 $MA_GEAR_STEP_MAX_VELO_LIMIT (maximum speed of gear stage with speed control)
MD35135 $MA_GEAR_STEP_PC_MAX_VELO_LIMIT (maximum speed of gear stage with position
control)
MD35140 $MA_GEAR_STEP_MIN_VELO_LIMIT (min. speed of gear stage)
35130
GEAR_STEP_MAX_VELO_LIMIT
rev/min
Maximum speed of gear stage
CTEQ
-
6
Description:
The maximum speed of the current gear stage for speed control mode (position control
not active) is configured in MD35130 $MA_GEAR_STEP_MAX_VELO_LIMIT. The speed setpoints
generated taking the override into account are limited to this speed.
Note:
288
50., 50., 400., 800.,
0.0
1500., 3000.
500., 500., 1000.,
1.0e-6
2000., 4000., 8000.
A06, A11, A04
S1
DOUBLE
NEW CONF
-
1/1
A06, A11, A04
A2, S1, V1
DOUBLE
NEW CONF
-
2/2
M
M
Parameter Manual
List Manual, 01/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced

Table of Contents