Machine data
3.3 Channel-specific machine data
22037
AUXFU_ASSIGN_SIM_TIME
-
Acknowledgment time
-
-
64
Description:
Acknowledgment time for auxiliary functions in ms.
See MD22010 $MC_AUXFU_ASSIGN_TYPE[n] (auxiliary function type)
22040
AUXFU_PREDEF_GROUP
-
Predefined auxiliary function groups
-
-
301
Description:
Group assignment of predefined auxiliary functions.
The predefined groups cannot be changed for indices 0, 1, 2, 3, 4, 22, 23, 24.
22050
AUXFU_PREDEF_TYPE
-
Predefined auxiliary function type
-
-
301
Description:
The address codes of the predefined auxiliary functions are fix.
This setting cannot be changed!
22060
AUXFU_PREDEF_EXTENSION
-
Predefined auxiliary function extension
-
-
301
Description:
Address extension for predefined auxiliary functions:
This setting can be changed only for indices 5 to 17 and 21!
22070
AUXFU_PREDEF_VALUE
-
Predefined auxiliary function value
-
-
301
Description:
Value of predefined auxiliary functions.
This setting cannot be changed!
180
0, 0, 0, 0, 0, 0, 0, 0, 0,
0
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,, ...
1, 1, 1, 1, 1, 1, 2, 2, 2,
0
2, 2, 4, 4, 4, 4, 4, 4, 3,
1, 1, 1,, ...
M, M, M, M, M, M, M,
-
M, M, M,M, M, M,, M,
M, M, M, M, M, M, M,
M...
0, 0, 0, 0, 0, 0, 1, 1, 1,
-1
1, 1, 1, 1, 1, 1, 1, 1, 1,
0, 0, 0,, ...
0, 1, 2, 17, 30, 6, 3, 4,
-
5, 19, 70, 40, 41, 42,
43, 44, 45, -1,...
C04
H2, S1
DWORD
PowerOn
0x7FFFFFF
2/2
C04
H2
DWORD
PowerOn
168
2/2
C04
H2
STRING
PowerOn
-
2/2
C04
H2
DWORD
PowerOn
99
2/2
C04
H2
DWORD
PowerOn
-
2/2
M
M
M
M
M