Siemens SINUMERIK 808D Parameter Manual page 403

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Special cases, errors, ... When the axes have been stopped with IS "Delete distance-to-go" the next
corresponding to ...
Note for the reader
DB3200
DBX6.4
Edge evaluation: Yes
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Special cases, errors, ... The main program level cannot be interrupted with the IS, but only with the
Note for the reader
DB3200
DBX6.6
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Special cases, er‐
rors, ...
corresponding to ...
Note for the reader
DB3200
DBX6.7
Edge evaluation: No
Parameter Manual
List Manual, 01/2017
program block is prepared with the new positions. After a "Delete distance-
to-go", geometry axes thus follow a different contour to the one originally
defined in the part program.
If G90 is programmed in the block after "Delete distance-to-go" it is at least
possible to approach the programmed absolute position. On the other hand,
with G91, the position originally defined in the part program is not reached in
the following block.
DB380x DBX2.2 (Distance-to-go / Spindle reset)
Function Manual Basic Functions K1
Program level abort
Signal(s) to channel (PLC → NCK)
Signal(s) updated: Cyclic
At each edge change 0 → 1 the actual program level being processed (sub‐
program level) is immediately aborted. Processing of the part program con‐
tinues at the next higher program level from the exit point.
No effect
IS "Reset".
Function Manual Basic Functions K1
Rapid traverse override active
Signal(s) to channel (PLC → NCK)
Signal(s) updated: Cyclic
The rapid traverse override between 0 and a maximum of 100% entered in
the PLC interface is channel-specific.
The rapid traverse override entered at the PLC interface is ignored.
When the rapid traverse override is inactive, the NC always uses 100% as
the internal override factor.
Note:
The 1st switch position of the gray-coded interface for the value is an excep‐
tion. Also here for "Rapid traverse override inactive", this override factor is
used and for axes, 0% is output as override value.
The rapid traverse override is inactive when G33 is active.
IS "Rapid traverse override" (DB3200 DBX5)
Function Manual Basic Functions V1
Feedrate override active
Signal(s) to channel (PLC → NCK)
Signal(s) updated: Cyclic
Detailed descriptions of interface signals
5.7 Channel-specific signals