27882
PART_COUNTER_MCODE
-
Workpiece counting with user-defined M command
-
-
3
Description:
If part counting is activated via MD27880 $MC_PART_COUNTER, the count pulse can be
triggered by a special M command.
Only then are the values defined here taken into account:
Meaning:
The part counters are incremented by 1 in the NST signal output of the M command
described, where:
MD27882 $MC_PART_COUNTER_MCODE[0] for $AC_TOTAL_PARTS
MD27882 $MC_PART_COUNTER_MCODE[1] for $AC_ACTUAL_PARTS
MD27882 $MC_PART_COUNTER_MCODE[2] for $AC_SPECIAL_PARTS
27920
TIME_LIMIT_NETTO_INT_TASK
s
Runtime limit of interpreter subtask
-
-
-
Description:
With MD27920 $MC_TIME_LIMIT_NETTO_INT_TASK, the maximum runtime of the interpreter
subtask is set. The interpreter subtask is started from the preprocessing task. If the
interpreter task does not end on its own within the time set with MD27920
$MC_TIME_LIMIT_NETTO_INT_TASK, it will be stopped and continued after a preprocessing
cycle.
27930
TIME_LIMIT_NETTO_EES_TASK
s
Runtime limit of the EES async. subtask
-
-
-
Description:
The maximum runtime of the EES async. subtask is set with this machine data. The EES
async. subtask is started from the preprocessing task. If the EES async. subtask does
not end automatically within the time set in this machine data, it will be stopped and
resumed after a preprocessing cycle.
28010
MM_NUM_REORG_LUD_MODULES
-
Number of blocks for local user variables in REORG (DRAM)
-
-
-
Description:
Defines the number of additional LUD data blocks available for the function REORG (see
Description of Functions, Channels, Mode Groups, Program Operation (K1)).
This value can be 0 if the function REORG is not used. The CNC always opens 12 LUD data
blocks, of which 8 are used for NC programs and 4 for the ASUBs.
An LUD data block is needed for each NC program and ASUB in which a local user variable
is defined. This value may have to be increased for the function REORG if a large IPO
buffer is present and a large number of short NC programs in which LUD variables are
defined are active (prepared NC blocks of the programs are located in the IPO buffer).
Parameter Manual
List Manual, 01/2017
2, 2, 2, 2, 2, 2, 2, 2, 2,
0
2, 2, 2, 2, 2, 2, 2, 2, 2,
2, 2, 2, 2...
0.005, 0.005, 0.005,
0.001
0.005, 0.005, 0.005,
0.005, 0.005...
0.008, 0.008, 0.008,
0.001
0.008, 0.008, 0.008,
0.008, 0.008...
8, 8, 8, 8, 8, 8, 8, 8...
0
3.3 Channel-specific machine data
C09
K1
BYTE
PowerOn
99
3/2
EXP, C01
-
DOUBLE
PowerOn
0.100
ReadOnly
EXP, C01
-
DOUBLE
PowerOn
0.100
ReadOnly
EXP, C02
V2, K1
DWORD
PowerOn
SLMAXNUMBE
1/1
ROF_USERMO
DULES
Machine data
M
S
S
M
209