Siemens SINUMERIK 808D Parameter Manual page 134

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Machine data
3.3 Channel-specific machine data
Bit 14 :
Bit 15 = 0:
Active electronic gearboxes remain active.
Bit 15 = 1:
Active electronic gearboxes are deactivated.
Bit 16 = 0:
The current setting of the master spindle (SETMS) is retained.
Bit 16 = 1:
Initial setting for the master spindle according to MD20090 $MC_SPIND_DEF_MASTER_SPIND
Bit 17 = 0:
The current setting of the master toolholder (SETMTH) is retained (relevant only if
tool or magazine management is active)
Bit 17 = 1:
Only if MD20124 $MC_TOOL_MANAGEMENT_TOOLHOLDER> 0: Initial setting for the master
toolholder according to MD20124 $MC_TOOL_MANAGEMENT_TOOLHOLDER.
Otherwise, the setting for the master spindle applies.
Bit 18 = 0:
Reference axis for G96/G961/G962 according to MD20100 $MC_DIAMETER_AX_DEF.
When using SCC with its own spindle reset, setting bit 18 = 1 is recommended (see also
MD20110: $MC_RESET_MODE_MASK, bit 18).
Bit 18 = 1:
Reference axis for G96/G961/G962 is retained.
Related to:
MD20120 $MC_TOOL_RESET_VALUE
MD20130 $MC_CUTTING_EDGE_RESET_VALUE
MD20150 $MC_GCODE_RESET_VALUES
MD20152 $MC_GCODE_RESET_MODE
MD20110 $MC_RESET_MODE_MASK
MD20121 $MC_TOOL_PRESEL_RESET_VALUE
20114
MODESWITCH_MASK
-
Interruption MDI by mode change
-
-
-
Description:
After program interruption in MDI mode (e.g. in order to carry out a measurement on
the workpiece and to correct the tool wear values or after tool breakage) the tool can
be manually withdrawn from the contour by changing into JOG mode.
In this case, the control stores the coordinates of the position of the interruption
and indicates the path differences traversed by the axes in JOG mode as "Repos offset".
When MDI mode is selected again, the axis is repositioned on the contour. This response
can be canceled by means of this machine data.
Bit 0 (LSB)= 0:
When MDI (JOG, JOGREF, JOGREPOS, MDIREF and MDIREPOS) are deselected in stopped
status, the system ASUB Repos is selected.
Bit 0 (LSB) = 1:
When MDI (JOG, JOGREF, JOGREPOS, MDIREF and MDIREPOS) are deselected in stopped
status, the system ASUB Repos is not selected.
Bit 1 (LSB) = 0:
If the NCK stops at a part program block in the program execution in which
repositioning is not possible, alarm 16916 is generated if an attempt is made to switch
to manual mode.
134
Reserved (basic frame)
0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0...
C03
DWORD
0
0xFFFF
K1
Reset
1/1
M
Parameter Manual
List Manual, 01/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced