18662

MM_NUM_SYNACT_GUD_BOOL

-
Number of configurable GUD variables of type Boolean
-
808d-me42
1
808d-me62
1
808d-te42
1
808d-te62
1
808d-mte40
9
808d-mte60
9
Description:
The MD18662 $MN_MM_NUM_SYNACT_GUD_BOOL[ ] can be used to extend individual GUD blocks
by additional channel-specific parameter areas of type Boolean. The GUD blocks are
differentiated by the field index:
MD18662 $MN_MM_NUM_SYNACT_GUD_BOOL[0] =
MD18662 $MN_MM_NUM_SYNACT_GUD_BOOL[1] =
MD18662 $MN_MM_NUM_SYNACT_GUD_BOOL[2] =
MD18662 $MN_MM_NUM_SYNACT_GUD_BOOL[3] =
MD18662 $MN_MM_NUM_SYNACT_GUD_BOOL[8] =
In each case, fields with the following properties are created:
Data type BOOL
Field size corresponding to <value> of the relevant machine data
Predefined names:
SYG_BS[ ] -> Synact parameter of type Boolean in the SGUD block
SYG_BM[ ] -> Synact parameter of type Boolean in the MGUD block
SYG_BU[ ] -> Synact parameter of type Boolean in the UGUD block
SYG_B4[ ] -> Synact parameter of type Boolean in the GUD4 block
....
SYG_B9[ ] -> Synact parameter of type Boolean in the GUD9 block
The parameters can be read and written both by the part program and also via
synchronous actions.
18663

MM_NUM_SYNACT_GUD_AXIS

-
Number of configurable GUD variables of type Axis
-
808d-me42
1
808d-me62
1
808d-te42
1
808d-te62
1
808d-mte40
9
808d-mte60
9
Description:
The MD18663 $MN_MM_NUM_SYNACT_GUD_AXIS[ ] can be used to extend individual GUD blocks
by additional channel-specific parameter areas of type AXIS. The GUD blocks are
differentiated by the field index:
MD18663 $MN_MM_NUM_SYNACT_GUD_AXIS[0] =
MD18663 $MN_MM_NUM_SYNACT_GUD_AXIS[1] =
MD18663 $MN_MM_NUM_SYNACT_GUD_AXIS[2] =
MD18663 $MN_MM_NUM_SYNACT_GUD_AXIS[3] =
MD18663 $MN_MM_NUM_SYNACT_GUD_AXIS[8] =
In each case, fields with the following properties are created:
Data type AXIS
Parameter Manual
List Manual, 01/2017
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
3.2 General machine data
N02
-
DWORD
PowerOn
32767
0/0
32767
0/0
32767
0/0
32767
0/0
32767
7/2
32767
7/2
<value> -> extension of the SGUD block
<value> -> extension of the MGUD block
<value> -> extension of the UGUD block
<value> -> extension of the GUD4 block
<value> -> extension of the GUD9 block
N02
-
DWORD
PowerOn
32767
0/0
32767
0/0
32767
0/0
32767
0/0
32767
7/2
32767
7/2
<value> -> extension of the SGUD block
<value> -> extension of the MGUD block
<value> -> extension of the UGUD block
<value> -> extension of the GUD4 block
<value> -> extension of the GUD9 block
Machine data
S
S
S
S
M
M
S
S
S
S
M
M
113