Siemens SINUMERIK 808D Parameter Manual page 517

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Par. No.
Name
p1462
Speed controller integral
time adaptation speed lower
Description: Sets the integration time of the speed controller before the adaptation speed range.
This value corresponds to the basic setting of the integral time of the speed controller without adaptation.
p1520
Torque limit upper/motoring
Description: Sets the fixed upper torque limit or the torque limit when motoring.
Note:
Negative values when setting the upper torque limit (p1520 < 0) can result in the motor accelerating in an
uncontrollable fashion.
The maximum value depends on the maximum torque of the connected motor.
Dependency: p1521
p1521
Torque limit lower/regenera‐
tive
Description: Sets the fixed lower torque limit or the torque limit when regenerating.
Note:
Positive values when setting the lower torque limit (p1521 > 0) can result in the motor accelerating in an
uncontrollable fashion.
The maximum value depends on the maximum torque of the connected motor.
Dependency: p1520
p1656
Activates current setpoint fil‐
ter
Description: Setting for activating/de-activating the current setpoint filter.
If not all of the filters are required, then the filters should be used consecutively starting from filter 1.
Dependency: The individual current setpoint filters are parameterized as of p1657.
p1657
Current setpoint filter 1 type 1
Description: Sets the current setpoint filter 1 as low pass (PT2) or as extended general 2nd-order filter.
● 1: Low pass: PT2
● 2: General 2nd-order filter
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1658
Current setpoint filter 1 de‐
nominator natural frequency
Description: Sets the denominator natural frequency for current setpoint filter 1 (PT2, general filter).
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1659
Current setpoint filter 1 de‐
nominator damping
Description: Sets the denominator damping for current setpoint filter 1.
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1660
Current setpoint filter 1 nu‐
merator natural frequency
Description: Sets the numerator natural frequency for current setpoint filter 1 (general filter)
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
Parameter Manual
List Manual, 01/2017
Min
Max
Factory
setting
0.00
100000.0
20.00
0
-1000000
2000000
0.00
.00
0.00
-2000000
1000000.
0.00
0.00
00
-
-
0001 bin -
2
1
0.5
16000.0
1999.0
0.001
10.000
0.700
0.5
16000.0
1999.0
SINAMICS parameters
7.1 SINAMICS V70 parameters
Unit
Data type
Effective
ms
Float
IM
Nm
Float
IM
Nm
Float
IM
U16
IM
-
I16
IM
Hz
Float
IM
-
Float
IM
Hz
Float
IM
Can be
changed
T, U
T, U
T, U
T, U
T, U
T, U
T, U
T, U
517

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced

Table of Contents