NC setting data
41050
JOG_CONT_MODE_LEVELTRIGGRD
-
Jog mode / continuous operation with continuous JOG
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
1:
In jog mode (default setting) the axis traverses as long as the traverse key is held
down and an axis limitation has not been reached. When the key is released the axis is
decelerated to zero speed and the movement is considered complete.
0:
In continuous operation the traverse movement is started with the first rising edge of
the traverse key and continues to move even after the key is released. The axis can be
stopped again by pressing the traverse key again (second rising edge).
SD irrelevant for ......
Incremental jogging (JOG INC)
Reference point approach (JOG REF)
41100
JOG_REV_IS_ACTIVE
-
JOG mode: revolutional feedrate / linear feedrate
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
Bit 0 = 0:
The behavior depends on the following:
- in the case of an axis/spindle:
- in the case of a geometry axis with an active frame with rotation:
- in the case of an orientation axis:
Bit 0 = 1:
A JOG motion with revolutional feedrate shall be traversed depending on the master
spindle.
The following must be considered:
- If a spindle is the master spindle itself, it will be traversed without revolutional
feedrate.
- If the master spindle is in stop position and if SD43300
$SA_ASSIGN_FEED_PER_REV_SOURCE (with an axis/spindle) or SD42600
$SC_JOG_FEED_PER_REV_SOURCE (with a geometry axis with an active frame with rotation,
or with an orientation axis) = -3, traversing will be carried out without revolutional
feedrate.
Bit 1 = 0:
322
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Jog mode for JOG continuous
Continuous operation for JOG continuous
0x0E
0x0E
0x0E
0x0E
0x0E
0x0E
on the axial SD43300 $SA_ASSIGN_FEED_PER_REV_SOURCE
on the channel-specific SD42600 $SC_JOG_FEED_PER_REV_SOURCE
on the channel-specific SD42600 $SC_JOG_FEED_PER_REV_SOURCE
-
BOOLEAN
0
-
0
-
0
-
0
-
0
-
0
-
-
BYTE
0
-
0
-
0
-
0
-
0
-
0
-
H1
Immediately
1/1
M
1/1
M
1/1
M
1/1
M
7/7
U
7/7
U
-
Immediately
1/1
M
1/1
M
1/1
M
1/1
M
7/7
U
7/7
U