CC408 | Quick Reference Guide | 3.
3.11.7
Pulsing Mode
When you program the output polarity as pulsing,
the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is
the time base, which is multiplied by the
multiplier. For example, if you want the output to
pulse 1 second ON and 5 seconds OFF, you would
program time base as one and the multiplier as
five.
3.12
Time Programming
3.12.1
Entry Time 1
Location
398 to 399
Increments of 1 second
(0 to 15 seconds)
Increments of 16 seconds
(0 to 240 seconds)
3.12.2
Entry Time 2
Location
400 to 401
Increments of 1 second
(0 to 15 seconds)
Increments of 16 seconds
(0 to 240 seconds)
3.12.3
Exit Time (AWAY/STAY Modes)
402 to 403
Location
Increments of 1 second
(0 seconds to 15 seconds)
Increments of 16 seconds
(0 seconds to 240 seconds)
3.12.4
Entry Guard Time For STAY Mode
Location
404 to 405
Increments of 1 second
(0 seconds to 15 seconds)
Increments of 16 seconds
(0 seconds to 240 seconds)
3.12.5
Delay Alarm Report Time
Location
406 to 407
Increments of 1 second
(0 seconds to 15 seconds)
Increments of 16 seconds
(0 seconds to 240 seconds)
3.12.6
Sensor Watch Time
408 to 409
Location
Increments of days
(tens digit)
Increments of days
(units digit)
Bosch Security Systems | 6/04 | 4998152468B
Programming Parameters
Location
Default
398
4
399
1
Location
Default
400
8
401
2
Location
Default
402
12
403
3
Location
Default
404
0
405
0
Location
Default
406
0
407
0
Location
Default
408
0
409
0
3.12.7
Codepad Lockout Time
Location
410
Default
0
0
No lockout
1 to 15
Increments of 10 seconds
(10 seconds to 150 seconds)
3.12.8
Siren Run Time
411
Location
Default
5
0
No siren time
1 to 15
Increments of 1 minute
(1 minute to 15 minutes)
3.12.9
Siren Sound Rate
Location
412
7
Default
0 to 15
0 = slowest frequency
15 = fastest frequency
3.12.10
Auto Arming Pre-Alert Time
Location
413
Default
1
0
No pre-alert time
1 to 15
Increments of 5 minutes
(5 minutes to 75 minutes)
3.12.11
Auto Arming Time
414 to 417
Location
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
3.12.12
Auto Disarming Time
Location
418 to 421
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
3.12.13
Kiss-Off Wait Time
Location
422
3
Default
Increments of 500 milliseconds
(500 ms to 8 seconds)
3.13
Reserved
Location
423
Default
0
3.14
System Options Programming
3.14.1
System Options 1
424
Location
1
Bosch Security Systems smart lockout allowed
2
Horn speaker monitor
4
Strobe indication for radio arm/disarm
8
Horn speaker beeps for radio arm/disarm
EN | 16
Location
Default
414
0
415
0
416
0
417
0
Location
Default
418
0
419
0
420
0
421
0