Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
Syntax of the Command Line Interface
Table 4- 30
Command
info
dhcpmode [mode]
clientid [ClientID]
cfgreq [E|D]
4.4.10

Time Config

4.4.10.1

Agent Time Configuration

Time-of-day synchronization in the network
The following protocols are available for time synchronization in the network:
● SNTP (Simple Network Time Protocol)
● NTP (Network Time Protocol)
● SIMATIC Time
● PTP (Precision Time Protocol)
Make the general settings in the "Agent Time Configuration" screen.
SNTP and NTP require further settings that you can make with the menu items "SNTP
Client" and "NTP Client".
116
Agent DHCP Configuration - CLI\AGENT\DHCPCONF>
Description
Shows the current DHCP configuration
Sets the DHCP mode. The possible modes are as fol-
lows:
MAC
MAC address
CLID
Client ID
SYSN
device name
DEVN
PNIO device name
Specifies the DHCP client ID. This value is used when
DHCP via client ID is set. The client ID can be freely
defined.
Enables/disables Config File Request (Opt. 66, 67)