Configuring Two VLL Paths Terminating on T-PE2
SDP3:300
PW switching
PW switching
SDP1:100
Figure 2: VLL Resilience with Pseudowire Redundancy and Switching
T-PE1
Example
7750 SR OS Services Guide
Access Node
7x50 T-PE2
7x50
7x50 S-PE3
7x50 S-PE1
7x50
7x50 T-PE1
Access Node
:
config>service# epipe 1 customer 1 vc-switching create
config>service>epipe$ endpoint x create
config>service>epipe>endpoint$ exit
config>service>epipe# endpoint y create
config>service>epipe>endpoint# revert-time 0
config>service>epipe>endpoint# exit
config>service>epipe# sap 1/1/1:100 endpoint x create
config>service>epipe>sap$ exit
config>service>epipe# spoke-sdp 1:100 endpoint y create
config>service>epipe>spoke-sdp$ revert-timer 0
config>service>epipe>spoke-sdp$ precedence primary
config>service>epipe>spoke-sdp$ exit
config>service>epipe# spoke-sdp 4:400 endpoint y create
config>service>epipe>spoke-sdp$ precedence 0
config>service>epipe>spoke-sdp$ no shutdown
config>service>epipe>spoke-sdp$ exit
config>service>epipe# no shutdown
7x50 T-PE3
Metro area B
7x50
7x50 S-PE4
Core area
7x50 S-PE2
SDP4:400
7x50
Metro area A
7x50
Virtual Leased Line Services
Primary PW
Standby PW
SDP6:600
PW switching
PW switching
OSSG114