Signaling Events and Alarms

SIGNALING (16)

To troubleshoot and correct the cause of the alarm, refer to the
section on page
DESCRIPTION
Link is Congested
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link No–ONE_BYTE
PRIMARY
Issued when the specified SS7 link is experiencing congestion.
CAUSE
PRIMARY
Monitor event reports at the network level to determine if the traffic load on the specified SS7 link is
ACTION
too high on the local end, or if the remote end is lagging in processing the traffic.
SECONDARY
Verify that the SS7 link has not degraded in quality.
ACTION
TERNARY
Verify that the traffic load has not become unbalanced if multiple SS7 links are used.
ACTION
SUBSEQUENT
Verify that local SS7 signaling adapter process is running normally.
ACTION
SIGNALING (17)
To troubleshoot and correct the cause of the alarm, refer to the
Outage—Signaling (17)" section on page
DESCRIPTION
Link: Local Processor Outage
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link No–ONE_BYTE
Link Name–STRING [8]
PRIMARY
Issued when the specified SS7 link has experienced a processor outage.
CAUSE
PRIMARY
Monitor the system for maintenance event reports associated with the signaling adapter or the
ACTION
underlying platform instances that support the specified SS7 link. Verify that the process and or
platform are restarted and returned to service.
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
10-10
10-134.