Audit Events and Alarms

AUDIT (19)

To monitor and correct the cause of the event, refer to the
(19)" section on page
DESCRIPTION
Recovered Memory of Stale Call
SEVERITY
WARNING
THRESHOLD
20
THROTTLE
0
DATAWORDS
Stale Memory Release Info–STRING [128]
PRIMARY
A loss of communication with originating or terminating side has occurred.
CAUSE
PRIMARY
Check to see if adjacent network element is up and has a proper communication link with the BTS
ACTION
10200.
SECONDARY
Adjacent network device protocol error has occurred.
CAUSE
SECONDARY
Check the adjacent network device protocol compatibility.
ACTION
TERNARY
An internal software error has occurred.
CAUSE
TERNARY
Contact Cisco Support. (Contact Cisco TAC.)
ACTION
Note
Refer to the
detailed instructions on contacting Cisco TAC and opening a service request.
Prior to contacting Cisco TAC, collect a trace log corresponding to the time of the alarm.