Database Events and Alarms

DATABASE (20)

To troubleshoot and correct the cause of the alarm, refer to the
Switchover—Database (20)" section on page
DESCRIPTION
Replication Data Flush Timeout During Switchover
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Tables Failed–STRING [20]
PRIMARY
An replication module software problem has occurred.
CAUSE
PRIMARY
The database restore procedure needs to be executed on the side of the system which goes active after
ACTION
the switchover. Any alarms should be cleared manually after the recovery action is taken.
DATABASE (21)
To troubleshoot and correct the cause of the alarm, refer to the
Exception—Database (21)" section on page
DESCRIPTION
Database Statistics Collection Exception (DB Statistics Collection Exception)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Host Name–STRING [30]
Database Name–STRING [10]
Schema Name–STRING [32]
Object Name–STRING [64]
Task Name–STRING [64]
Exception–STRING [256]
PRIMARY
Check the messages in the Exception dataword field to identify the cause of the error.
CAUSE
PRIMARY
The correction action varies and is determined by the type of exception. For more information about
ACTION
the ORA-xxxxx errors, execute the oerr ora xxxxx command as an Oracle user.