Signaling (64) - Cisco BTS 10200 Troubleshooting Manual

Softswitch
Hide thumbs Also See for BTS 10200:
Table of Contents

Advertisement

Chapter 10
Signaling Troubleshooting

SIGNALING (64)

To troubleshoot and correct the cause of the alarm, refer to the
Shared Memory Pools—Signaling (64)" section on page
DESCRIPTION
Media Gateway Adapter Running out of Shared Memory Pools (MGA Running out of Shared Memory
Pools)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
PRIMARY
Issued when the Media Gateway Control Protocol (MGCP) signaling adapter was unable to allocate
CAUSE
data storage for an inter-process communication (IPC) message due to a lack of resources.
PRIMARY
Call Cisco TAC technologies for assistance. (Contact Cisco TAC.)
ACTION
Refer to the
Note
detailed instructions on contacting Cisco TAC and opening a service request.
SIGNALING (65)
To troubleshoot and correct the cause of the alarm, refer to the
Heap Memory—Signaling (65)" section on page
DESCRIPTION
Media Gateway Adapter Running out of Heap Memory (MGA Running out of Heap Memory)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
PRIMARY
Issued when the MGCP signaling adapter was unable to allocate data storage for an IPC message from
CAUSE
the heap due to a lack of resources.
PRIMARY
Call Cisco TAC Technologies for assistance. (Contact Cisco TAC.)
ACTION
Refer to the
Note
detailed instructions on contacting Cisco TAC and opening a service request.
OL-8723-19
"Obtaining Documentation and Submitting a Service Request" section on page lvi
"Obtaining Documentation and Submitting a Service Request" section on page lvi
"Media Gateway Adapter Running out of
10-138.
"Media Gateway Adapter Running out of
10-138.
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
Signaling Events and Alarms
for
for
10-35

Advertisement

Table of Contents
loading

Table of Contents