4
The following table describes the LEDs for the 48-Port 32-Gbps Fiber Channel Switching Module.
Table 10: Cisco MDS 48-Port 32-Gbps Fiber Channel Switching Module LEDs
LED
Status
ID
Link
Cisco MDS 48-Port 16-Gbps Fiber Channel Switching Module
The Cisco MDS 9700 48-Port 16-Gbps Switching Module is designed specifically for the Cisco MDS 9700
Series Director Switches. These modules are hot-swappable and compatible with 2, 4, 8, 10, and 16-Gbps
interfaces, and they support hot-swappable Enhanced Small Form-Factor Pluggable (SFP+) transceivers.
Cisco MDS 9700 Series Switches Hardware Installation Guide
44
Status LED
Status
Description
Green
All diagnostics pass. The module is operational (normal initialization
sequence).
Orange
One of the following occurs or occurred:
• The module is booting or running diagnostics (normal initialization
sequence).
• An over temperature condition has occurred. (A minor temperature
threshold has been exceeded during environmental monitoring.)
Blinking Red
One of the following occurs:
• The module is resetting. The switch has been powered on or the
module has been hot inserted during the normal initialization
sequence.
• An over temperature condition has occurred. (A major temperature
threshold has been exceeded during environmental monitoring.)
• If the module fails to download code and configuration information
successfully during the initial reset, the LED stays blinking red;
the module does not come online.
Solid Red
The module has detected a slot ID parity error on the mid plane. The
module cannot determine its slot number and will not respond to the
supervisor.
Off
The module is not receiving power.
Blinking blue
The operator has activated this LED to identify this module in the chassis.
Off
This module is not selected.
The port is active (the link is connected and operational).
Green
Solid Orange
SFP is not present or Admin is down.
Blinking Orange
A fault condition exists.
Off
The port is not active or the link is not connected.