Signaling Troubleshooting

SIGNALING (108)

To troubleshoot and correct the cause of the alarm, refer to the
Mode—Signaling (108)" section on page
DESCRIPTION
Simplex Only Operational Mode
SEVERITY
MAJOR
THRESHOLD
30
THROTTLE
0
DATAWORDS
Host Domain Name–STRING [128]
PRIMARY
The hostname parameter is specified in the platform.cfg file instead of -contact parameter.
CAUSE
PRIMARY
The BTS 10200 is configured as a SIMPLEX system.
ACTION
SIGNALING (109)
To troubleshoot and correct the cause of the alarm, refer to the
Association Failure—Signaling (109)" section on page
DESCRIPTION
Stream Control Transmission Protocol Association Failure (SCTP Association Failure)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
SCTP Association ID–STRING [17]
PRIMARY
The Ethernet cables for the signaling gateway process (SGP) are unplugged or severed.
CAUSE
PRIMARY
Plug Ethernet cables in or fix the severed connection.
ACTION
SECONDARY
SGP is not operational.
CAUSE
SECONDARY
Check the SGP alarms to determine why it is not operating properly.
ACTION