Chapter 15
Diagnostic Tests
Configuration Examples
The following example describes the steps required to configure the originating line (media gateway
profile) to identify a network loopback call.
These tasks include examples of CLI commands that illustrate how to provision the specific feature.
Note
Most of these tables have additional tokens that are not included in the examples. For a complete list of
all CLI tables and tokens, see the BTS 10200 Command Line Interface Reference Guide.
Global Configuration Example
Use the following procedure as a global configuration example.
Add ca-config NLB-TEST-SERVICE-AFFECTING.
Step 1
add ca-config type=NLB-TEST-SERVICE-AFFECTING; value=N
Step 2
Add ca-config NCT-TEST-SERVICE-AFFECTING.
add ca-config type=NCT-TEST-SERVICE-AFFECTING; value=N;
Step 3
Add ca-config TEST-TRUNK-GRP-DIGITS.
add ca-config type=TEST-TRUNK-GRP-DIGITS; value=4;
Add ca-config TEST-TRUNK-MEMBER-DIGITS.
Step 4
add ca-config type=TEST-TRUNK-MEMBER-DIGITS; value=4;
OL-8723-19
Network Loopback Test for Network-based Call Signaling/Media Gateway Control Protocol Endpoints
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
15-43