Automatic Restart

Troubleshooting

The following troubleshooting procedure can be used any time a platform side goes OOS due to a fault.
Note
Troubleshooting of a platform shutdown can be completed using the Automatic Restart feature
saved.debug directory. When a platform shutdown occurs, useful debugging information (cores, logs,
etc.) is saved and compressed in a tar file. This file is located in the directory
<platform>/bin/saved.debug. To recover the tar file information and to clear the tar file disk space,
complete the following steps:
Step 1
Download the timestamped tar file from the saved.debug directory to a system for offline debugging. An
example filename is: saved.debug.2007_02_16__16_07_09.tar.Z.
Remove the tar file from the disk after it is downloaded to conserve disk space.
Step 2
Switchover in Progress–Maintenance (101)
The Switchover in Progress alarm (critical) indicates that a system switchover is in progress. This alarm
is issued when a system switchover is in progress either due to manual switchover (by a CLI command),
failover switchover, or automatic switchover. For additional information, refer to
(101).
Side Automatically Restarting Due to Fault–Maintenance (117)
The Side Automatically Restarting Due to Fault alarm (critical) indicates that a platform side is
automatically restarting due to a fault condition. This alarm indicates that an Automatic Restart is
pending and at what time it will be attempted. For additional information, refer to
(117).