Audit (3) - Cisco BTS 10200 Troubleshooting Manual

Softswitch
Hide thumbs Also See for BTS 10200:
Table of Contents

Advertisement

Chapter 2
Audit Troubleshooting

AUDIT (3)

To monitor and correct the cause of the event, refer to the
Code Audit Terminated Before Successful Completion—Audit (3)" section on page
DESCRIPTION
Signaling System 7 Circuit Identification Code Audit Terminated Before Successful Completion (SS7
CIC Audit Terminated Before Successful Completion)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Type of Audit–STRING [64]
PRIMARY
A higher priority SS7 CIC audit interrupted and terminated a lower priority SS7 CIC audit.
CAUSE
PRIMARY
Do not schedule an SS7 remote termination audit to occur while a periodic SS7 local termination audit
ACTION
is executing.
AUDIT (4)
To monitor and correct the cause of the event, refer to the
Threshold—Audit (4)" section on page 2-18
DESCRIPTION
Call Exceeds a Long-Duration Threshold
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Trunk group number–TWO_BYTES
Trunk member number–TWO_BYTES
Current long-duration threshold–TWO_BYTES
PRIMARY
A call exceeded the current system long-duration threshold.
CAUSE
PRIMARY
If there is a reason to believe the call is no longer valid, release the associated trunk facility.
ACTION
OL-8723-19
"Signaling System 7 Circuit Identification
"Call Exceeds a Long-Duration
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
Audit Events and Alarms
2-18.
2-3