Signaling Events and Alarms

SIGNALING (139)

For additional information, refer to the
State—Signaling (139) (SS7)" section on page
DESCRIPTION
Signaling System 7 Trunk was Found to be in Erroneous State (SS7 Trunk was Found to be in
Erroneous State)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
Near-End State–STRING [64]
Far-End State–STRING [64]
Resolution Action–STRING [64]
PRIMARY
A discrepancy between the local and the remote trunk states has occurred.
CAUSE
PRIMARY
Automatic corrective action is enforced when using American National Standards Institute (ANSI)
ACTION
ISUP.
SIGNALING (140)
For additional information, refer to the
on page
DESCRIPTION
Unanswered Information Message (Unanswered INF Message)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
The far-end switch is not responding to an information (INF) message with an information request
CAUSE
(INR) message.
PRIMARY
Verify that the far-end switch can correctly respond to an INF message.
ACTION
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
10-74
10-119.
"Signaling System 7 Trunk was Found to be in Erroneous
10-119.
"Unanswered Information Message—Signaling (140)" section
Chapter 10
Signaling Troubleshooting