Signaling (30) - Cisco BTS 10200 Troubleshooting Manual

Softswitch
Hide thumbs Also See for BTS 10200:
Table of Contents

Advertisement

Chapter 10
Signaling Troubleshooting

SIGNALING (30)

To monitor and correct the cause of the event, refer to the
Message—Signaling (30)" section on page
DESCRIPTION
Unanswered Circuit Validation Test Message (Unanswered CVT)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
Issued when a circuit validation test (CVT) message was not acknowledged before the Tcvt expired
CAUSE
for the associated CIC.
PRIMARY
Verify that the SS7 signaling adapter processes is running normally.
ACTION
SECONDARY
Verify that the call agent platform is active.
ACTION
TERNARY
Verify that the SS7 interface hardware is in service.
ACTION
SUBSEQUENT
Verify that the associated SS7 signaling link is available. Verify that the T13 timer is set to an
ACTION
appropriate level. Verify that the SS7 link is not congested.
OL-8723-19
"Unanswered Circuit Validation Test
10-102.
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x