Signaling Events and Alarms

SIGNALING (173)

To troubleshoot and correct the cause of the alarm, refer to the
Resolved Into Any IP Address —Signaling (173)" section on page
DESCRIPTION
ENUM Server Domain Cannot be Resolved into Any IP Address
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
ENUM Server Domain - STRING [128]
ENUM Profile ID - STRING [64]
PRIMARY
Misconfiguration in the DNS.
CAUSE
PRIMARY
Fix the configuration in the DNS according to the documentation.
ACTION
SIGNALING (174)
To troubleshoot and correct the cause of the alarm, refer to the
(174)" section on page
DESCRIPTION
ENUM Server Unavailable
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
ENUM Server IP Address - STRING [16]
ENUM Server Farm Name - STRING [128]
ENUM Profile ID - STRING [64]
PRIMARY
A network or server problem has occurred.
CAUSE
PRIMARY
Fix the network or server problem.
ACTION