Logical Internet Protocol Addresses Not Mapped Correctly—Signaling (107) - Cisco BTS 10200 Troubleshooting Manual

Softswitch
Hide thumbs Also See for BTS 10200:
Table of Contents

Advertisement

Monitoring Signaling Events
Enhanced Subscriber Authentication BTS 10200 Delivery Function Connection
Down—Signaling (106)
The Enhanced Subscriber Authentication BTS 10200 Delivery Function Connection Down alarm
(minor) indicates that the enhanced subscriber authentication (ESA) BTS 10200 DF connection is down.
To troubleshoot and correct the cause of the Enhanced Subscriber Authentication BTS 10200 Delivery
Function Connection Down alarm, refer to the
Delivery Function Connection Down—Signaling (106)" section on page
Logical Internet Protocol Addresses not Mapped Correctly—Signaling (107)
The Logical Internet Protocol Addresses not Mapped Correctly alarm (critical) indicates that the logical
IP addresses are not mapped correctly. To troubleshoot and correct the cause of the Logical Internet
Protocol Addresses not Mapped Correctly alarm, refer to the
Mapped Correctly—Signaling (107)" section on page
Simplex Only Operational Mode—Signaling (108)
The Simplex Only Operational Mode alarm (major) indicates that the BTS 10200 system can only
operate in the simplex mode. To troubleshoot and correct the cause of the Simplex Only Operational
Mode alarm, refer to the
Stream Control Transmission Protocol Association Failure—Signaling (109)
The Stream Control Transmission Protocol Association Failure alarm (major) indicates that the SCTP
association failed. To troubleshoot and correct the cause of the Stream Control Transmission Protocol
Association Failure alarm, refer to the
Failure—Signaling (109)" section on page
Signaling Gateway Group is Out-of-Service—Signaling (110)
The Signaling Gateway Group is Out-of-Service alarm (major) indicates that the signaling gateway
group is out-of-service. To troubleshoot and correct the cause of the Signaling Gateway Group is
Out-of-Service alarm, refer to the
section on page
Stream Control Transmission Protocol Association Degraded (One of Two
Internet Protocol Connections Down)—Signaling (111)
The Stream Control Transmission Protocol Association Degraded (One of Two Internet Protocol
Connections Down) alarm (major) indicates that the SCTP association is degraded. To troubleshoot and
correct the cause of the Stream Control Transmission Protocol Association Degraded (One of Two
Internet Protocol Connections Down) alarm, refer to the
Association Degraded (One of Two Internet Protocol Connections Down)—Signaling (111)" section on
page
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
10-114
"Simplex Only Operational Mode—Signaling (108)" section on page
10-150.
10-150.
"Enhanced Subscriber Authentication BTS 10200
10-145.
"Stream Control Transmission Protocol Association
10-146.
"Signaling Gateway Group Is Out-of-Service—Signaling (110)"
"Stream Control Transmission Protocol
Chapter 10
Signaling Troubleshooting
10-144.
"Logical Internet Protocol Addresses not
10-145.