Signaling Events and Alarms

SIGNALING (120)

To troubleshoot and correct the cause of the alarm, refer to the
System 7 Adapter Faulty—Signaling (120)" section on page
DESCRIPTION
Signaling System 7 Module/Signaling System 7 Adapter Faulty (S7M/S7A Faulty)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Reason–STRING [36]
PRIMARY
An OMNI failure has occurred.
CAUSE
PRIMARY
Check the OMNI status; a failover will occur in a duplex configuration.
ACTION
SIGNALING (121)
To troubleshoot and correct the cause of the alarm, refer to the
Cannot Go Standby—Signaling (121)" section on page
DESCRIPTION
Message Transfer Part 3 User Adapter Cannot Go Standby (M3UA/SUA Cannot Go Standby)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Platform ID–STRING [17]
PRIMARY
No INACTIVE acknowledge (ACK) messages are received from any SG or SCTP. The associations
CAUSE
are probably down.
PRIMARY
Investigate any other alarms to see if SGs are down or the SCTP associations are down. Take corrective
ACTION
action according to those alarms.