Maintenance Events and Alarms

MAINTENANCE (3)

To troubleshoot and correct the cause of the alarm, refer to the
Faulty—Maintenance (3)" section on page
DESCRIPTION
Keep Alive Module: Local Side has Become Faulty (KAM: Local Side Has Become Faulty)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Local State–STRING [30]
Mate State–STRING [30]
Reason–STRING [80]
Probable Cause–STRING [80]
PRIMARY
Can result from maintenance reports 5, 6, 9, 10, 19, or 20.
CAUSE
PRIMARY
Review the information from the command line interface (CLI) log report. Usually a software problem;
ACTION
restart the software using the installation and startup procedure.
SECONDARY
Manually shutting down the system using platform stop command.
CAUSE
SECONDARY
Reboot the host machine, reinstall all applications and restart all applications. If the fault state is a
ACTION
commonly occurring problem, then the operating system (OS) or a hardware failure may be the
problem.
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
7-4
Chapter 7
"Local Side has Become
7-92.
Maintenance Troubleshooting
OL-8723-19