Billing Events and Alarms

BILLING (46)

To troubleshoot and correct the cause of the alarm, refer to the
(46)" section on page
DESCRIPTION
Event Message Log File Closed
SEVERITY
MINOR
THRESHOLD
50
THROTTLE
0
DATAWORDS
Element Type–STRING [5]
File Name–STRING [60]
Location Tag–STRING [30]
PRIMARY
An open event message log file has been closed.
CAUSE
PRIMARY
No action is necessary.
ACTION
BILLING (47)
To troubleshoot and correct the cause of the alarm, refer to the
for One Hour—Billing (47)" section on page
DESCRIPTION
Record Keeping System Unreachable for One Hour (RKSs Unreachable for 1 Hour)
SEVERITY
MINOR
THRESHOLD
25
THROTTLE
0
DATAWORDS
Location Tag–STRING [30]
PRIMARY
Billing has not been able to communicate with any RKS for the past one hour.
CAUSE
PRIMARY
Check status of the primary and secondary RKS servers; attempt to bring them into service. Verify that
ACTION
the radius-profile table and call-agent-profile table are provisioned such that communication with the
RKS servers is possible.