Maintenance Troubleshooting

MAINTENANCE (58)

For additional information, refer to the
Levels—Maintenance (58)" section on page
Note
Maintenance (58) is issued by the BTS 10200 system when memory consumption is greater than 80
percent (>80%) and swap space consumption is greater than 30 percent (>30%).
DESCRIPTION
Memory and Swap are Consumed at Abnormal Levels
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Host Name–STRING [40]
Memory–STRING [40]
Swap–STRING [40]
PRIMARY
A process or multiple processes have consumed an abnormal amount of memory on the system and the
CAUSE
operating system is utilizing an abnormal amount of the swap space for process execution. This can be
a result of high call rates or bulk provisioning activity.
PRIMARY
Monitor the system to ensure all subsystems are performing normally. If they are, only lightening the
ACTION
effective load on the system will clear the situation. If they are not, verify which process(es) are
running at abnormally high rates, provide the information to Cisco TAC. (Contact Cisco TAC.)
Note
Refer to the
detailed instructions on contacting Cisco TAC and opening a service request.
MAINTENANCE (59)
MAINTENANCE (59) is not used.
MAINTENANCE (60)
MAINTENANCE (60) is not used.
OL-8723-19
"Obtaining Documentation and Submitting a Service Request" section on page lvi
"Memory and Swap are Consumed at Abnormal
7-79.
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
Maintenance Events and Alarms