Subscriber Termination Tests

Subscriber Termination Tests
This section describes the tests that can be performed on subscriber terminations. All terminations must
be in the MAINT state.
Force the subscriber termination into MAINT state:
Step 1
control subscriber-termination id=sub2-ctx2; mode=forced; target-state=maint;
Display the Test Menu.
Step 2
diag subscriber-termination;
Reply Example:
Reply: Diagnostic Subscriber Menu.
===
(1) Subscriber MGCP Connectivity Test
(2) Subscriber Termination Connection Test
(3) Subscriber Termination Ring Test
(4) ALL
Test #1 tests if MGCP has access to the termination.
Note
Test #2 tests if there is a path to the device (ping).
Test #3 tests if the subscriber can be rung. The Ring parameter must be specified in seconds for this test.
The default is 5 seconds.
Test #4 performs tests 1 through 3.