Chapter 15
Diagnostic Tests
Signaling System 7 Trunk Termination Tests
To perform a specific test, use the following examples as a guide:
Step 3
diag ss7-trunk-termination tgn-id=103; cic=13; test=1;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 103
CIC -> 13
TEST-TYPE -> ADM-MGW-MGCP-CONNECTIVITY-TEST
TEST-DURATION -> 0
RESULT -> TEST-SUCCESS
REASON -> PASSED: Reason: AUEP-NACK received with RespCode = 510
Reply: Diagnostic command executed.
diag ss7-trunk-termination tgn-id=103; cic=13; test=2;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 103
CIC -> 13
TEST-TYPE -> ADM-TERM-CONNECTION-TEST
TEST-DURATION -> 33
RESULT -> TEST-SUCCESS
REASON -> PASS successfully.
Reply: Diagnostic command executed.
diag ss7-trunk-termination tgn-id=103; cic=14; test=3;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 103
CIC -> 14
TEST-TYPE -> ADM-SS7-COT-TEST
TEST-DURATION -> 0
RESULT -> TEST-FAILURE
REASON -> ADM-MAINT-STATE-REQUIRED
Reply: Diagnostic command executed.
diag ss7-trunk-termination tgn-id=2;cic=1-24;test=4
Reply Example:
Reply : Success:
TGN ID -> 2
START CIC -> 1
END CIC -> 24
TEST TYPE -> ADM running SS7 circuit query message test
TEST DURATION -> 0
RESULT -> ADM ran test successfully
REASON -> CQM test pass
CIC COUNT -> 24
CIC STATES ->