Chapter 10
Signaling Troubleshooting

SIGNALING (151)

To troubleshoot and correct the cause of the alarm, refer to the
(151)" section on page
DESCRIPTION
Subscriber Line Faulty
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
End Point /Termination - STRING [54]
Media Gateway Type - STRING [54]
Error Details - STRING [54]
PRIMARY
The residential gateway returned an error code in response to a command from the MGW.
CAUSE
PRIMARY
Try controlling subscriber termination to OOS and back to INS using the BTS 10200 CLI command.
ACTION
If the problem persist after more calls, check the configuration in the BTS 10200 and the RGW. If the
error codes returned by the MGW are harmless, it can be suppressed by adding a new entry in
MGCP-RETCODE-ACTION table and by changing the EP-ACTION to RESET/NONE.
SIGNALING (152)
For additional information, refer to the
section on page
DESCRIPTION
Termination Transient Error Received
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Entity Name–STRING [40]
General Context–STRING [40]
Specific Context–STRING [40]
Failure Context–STRING [40]
PRIMARY
MGCP signaling interop errors have occurred.
CAUSE
PRIMARY
Notify customer support. (Contact Cisco TAC.)
ACTION
Refer to the
Note
detailed instructions on contacting Cisco TAC and opening a service request.
OL-8723-19
10-156.
10-121.
"Obtaining Documentation and Submitting a Service Request" section on page lvi
"Subscriber Line Faulty—Signaling
"Termination Transient Error Received—Signaling (152)"