Vision VR48 Machine Configuration

The VR48 Router must be configured for the DACS Camera. Open the menu by pressing the Menu
button on the Pendant.
Scroll down to highlight DACS and press the Enter button on the Pendant.
To adjust or set any of the parameters, scroll down and highlight the setting and press the Enter button
on the Pendant. There are two menu screens as shown below.
The Fiducial Diameter should be set to 0.25. To set this value, highlight Fiducial Diameter and press the
Enter button on the Pendant, enter 0.25 using the Pendant's numeric keypad, then press Enter on the
keypad.
The Correlation should be set to 0.9000. To set this value, highlight Correlation, press Enter, enter
0.9000 and press Enter to set this value.