Configuring Date/Time Publishing To Terminals (Optional); Enable Sending Of Date And Time On Isdn Dss1 Network Interfaces; Defining The 'Network-Type' In Isdn Interfaces; Isdn Explicit Call Transfer Support (& Sip Refer Transmission) - Patton electronics SmartWare R.3.20 Software Configuration Manual

Software for smartnode series
Table of Contents

Advertisement

SmartWare Software Configuration Guide
Configuring date/time publishing to terminals (optional)
ISDN allows to propagate current time and date information from a port configured as network to the con-
nected terminals. You can configure each ISDN interface to propagate the current SmartNode system time and
date to the connected terminals with the following command:
Procedure: To configure date and time publishing
Mode: Interface ISDN
Step
1
node (if-isdn)[ if-name ]#[no] isdn-date-time Enable/disable publishing of system time to con-
Date and time information can only be contained in the ISDN CONNECT message. This message is only
delivered to a terminal when a call from the terminal to the SmartNode is made, and reaches connected state.

Enable sending of date and time on ISDN DSS1 network interfaces

This procedure enables sending of date and time information on an ISDN network side interface.
Mode: interface isdn <if-name>
Step
1
[ name ] (if-isdn)[ if-name ]# isdn-date-time
Defining the 'network-type' in ISDN interfaces
The following command defines the location code to be inserted in ISDN causes code information elements.
Mode: interface isdn <if-isdn>
Step
1
[ name ] (if-isdn)[ if-name ]# network-type
[international|private|public|transit|user}
ISDN Explicit Call Transfer support (& SIP REFER Transmission)
Additional call transfer support is enabled by default for ISDN interfaces (BRI ports) by accepting or rejecting
explicit call-transfer (ECT) invocations. An ISDN phone that is connected to a BRI port and that has two
active calls can send an ECT invocation to connect the two calls inside the device. An ISDN interface can be
configured to accept or reject ECT invocations.
SmartWare detects calls that are looped internally, i.e. calls that leave the device over the same ISDN interface
over which they enter the device. If an internal loop is detected for an ISDN interface bound by an ISDN user
port, SmartWare sends an explicit call-transfer (ECT) to push back the call to the connected network as soon
as the call is connected. An ISDN interface can be configured to emit ECT invocations.
SIP interfaces react similarly to internally looped calls. If a call leaves the device over the same SIP gateway over
which it entered the device, SmartWare sends a REFER message to one of the remote user agents to transfer
the call to the two parties. A SIP interface can be configured to emit REFER messages.
ISDN interface configuration task list
Command
Command
Command
28 • ISDN interface configuration
Purpose
nected ISDN terminals (default: disabled)
Purpose
Enable sending of date and time.
Defines the type of network to which the system
belongs.
Purpose
335

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartware release 3.20

Table of Contents