Patton electronics SmartWare R.3.20 Software Configuration Manual page 104

Software for smartnode series
Table of Contents

Advertisement

SmartWare Software Configuration Guide
servers are down or the network is not reachable, you can create an emergency user in the local database so that
you can still access the SmartNode. Perform the following steps to configure the local accounts.
Mode: Configure
Step
node(cfg)#[no] administrator name pass-
1
word password
node(cfg)#[no] operator name password
2
password
3
node(radius)[name]#shared-secret
authentication secret
4
node(pf-auth)[name]#show accounts
Example: Create an administrator and an operator account
node>enable
node#configure
node(cfg)#administrator meier password pencil
node(cfg)#operator james password ""
node(cfg)#show accounts
Administrator accounts:
meier
Operator accounts:
james
node(cfg)
Note
If you are creating an account that does not require a password, type "" to
indicate that no password is needed. For example, if you were configuring an
account for an operator named James that did not need a password, the
entry would be:
node(cfg)#operator james password ""
Configuring the local database accounts
Command
8 • RADIUS Client Configuration
Purpose
Adds an administrator account to the local data-
base. The no form removes an existing account
Adds an operator account to the local database.
The no form removes an existing account
Sets the password shared between the RADIUS
client (the SmartNode) and the remote RADIUS
server.
Display existing accounts
104

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartware release 3.20

Table of Contents