Step
4
node (q931)[slot/port]#max-calls number-
of-calls
or
node (q931)[slot/port]#no max-calls
5
node (prt-pstn)[ slot/port ]#channel-range
min max
or
node (prt-pstn)[ slot/port ]#no channel-
range
6
node (q931)[slot/port]# bchan-number-
order ascending
or
node (q931)[slot/port]#bchan-number-
order ascending-cyclic
or
node (q931)[slot/port]#bchan-number-
order descending
or
node (q931)[slot/port]#bchan-number-
order descending-cyclic
7
node (q931)[ slot/port ]#encapsulation cc-
isdn
or
node (q931)[ slot/port ]#no encapsulation
8
node (prt-e1)[ slot/port ]#bind interface
interface
ISDN port configuration task list
Command
35 • ISDN port configuration
Purpose
Limits the total number of concurrent calls
on the port.
The no form of the command restores the
default settings.
if the channel-range and
Note
max-calls command are
used simultaneously, the
lower number of chan-
nels is the limiting
parameter.
Specify B-channel range to be used on a PRI
port (Default: E1: 0-31, T1: 0-23)
Limits the time-slots to be used for calls to the
range between min and max . This is in some
cases required for interoperability with ISDN
services that impose the same limitations.
Call slots outside the defined range are
rejected (busy line). If no range is defined
(Default) all 30 (T1: 23) time-slots are avail-
able for use.
The no form of the command restores the
default settings.
Specify B-channel allocation strategy (Default:
ascending)
The numbering mode defines how the avail-
able time slots are filled. The cyclic modes use
a "round-robin" implementation. The "up"
and "down" modes define whether the time
slots are filled at the lowest or highest avail-
able slot, i.e. up means that always the lowest
available slot is used, down uses always the
highest available slot.
Specify encapsulation of port.
Currently only CC-ISDN is supported.
The no form of the command removes an
existing encapsulation.