Configuring Call-Hold On Isdn Interfaces; Enabling Display Information Elements On Isdn Ports; Configuring Date/Time Publishing To Terminals (Optional) - Patton electronics SmartNode Series Software Configuration Manual

Software for smartnode series
Hide thumbs Also See for SmartNode Series:
Table of Contents

Advertisement

SmartWare Software Configuration Guide
Configuring Call-Hold on ISDN interfaces
Normally, the call-hold feature is disabled on ISDN point-to-point links and enabled on ISDN point-to-mul-
tipoint links. However, you can manually enable or disable the Call-Hold feature using the following com-
mand: The default setting can be achieved using the 'auto' configuration option.
Mode: interface isdn
Step
1
node(if-isdn)[if-name]# call-hold
{auto|enable|disable}

Enabling Display Information Elements on ISDN Ports

By default no display information elements are sent in ISDN signaling messages. You can enable sending of
ISDN Display Information elements in ISDN signaling messages using the following command.
Mode: interface isdn
Step
1
node(if-isdn)[if-name]# [no] display
emit
Configuring date/time publishing to terminals (optional)
ISDN allows to propagate current time and date information from a port configured as network to the con-
nected terminals. You can configure each ISDN interface to propagate the current SmartNode system time and
date to the connected terminals with the following command:
Procedure: To configure date and time publishing
Mode: Interface ISDN
Step
1
node(if-isdn)[if-name]#[no] isdn-date-time Enable/disable publishing of system time to con-
Date and time information can only be contained in the ISDN CONNECT message. This message is only
delivered to a terminal when a call from the terminal to the SmartNode is made, and reaches connected state.
ISDN interface configuration task list
Command
Command
Command
34 • ISDN interface configuration
Purpose
Enable or disable the call-hold functionality for
an isdn interface. If 'auto' is selected, call-hold is
automatically disabled on p2p links and enabled
on p2mp links.
Default: auto
Purpose
Enable sending of the display information ele-
ment for an isdn interface.
Default: disabled
Purpose
nected ISDN terminals (default: disabled)