SmartWare Software Configuration Guide

Introduction

This chapter provides an overview of the T1/E1 ports, their characteristics and the tasks involved in
the configuration.
The configurable parameters for the T1/E1 port are type (T1 or E1), clock mode (or source) (master or slave),
line code (AMI, HDB3, or B8ZS), framing (CRC-4, ESF, or unframed), line-build-out (for T1 only) and
encapsulation (channelized or HDLC).
A further feature is the creation and configuration of channel-groups.
T1/E1 port configuration task list
This section describes the configuration tasks for the T1/E1 port.

Enable/Disable T1/E1 port

Configuring the T1/E1 port type
Configuring T1/E1 clock mode
Configuring T1/E1 line code
Configuring T1/E1 framing
Configuring T1 line build out (LBO) (T1 only)
Configuring E1 impedance/connector
Configuring T1/E1 application mode
Configuring T1/E1 LOS threshold
Configuring T1/E1 encapsulation
Create a Channel-Group
Configuring channel-group timeslots
Configuring channel-group encapsulation
Entering HDLC configuration mode
Configuration HDLC CRC-type
Configuring HDLC encapsulation

Enable/Disable T1/E1 port

By default, the T1/E1 port is disabled. The following command is used for enabling or disabling it.
Mode: port e1t1 <slot> <port>
Step
[ name ] (prt-e1t1)[slot/port]# [no]
1
shutdown

Introduction

Command
15 • T1/E1 port configuration
Purpose
Enable/Disable the T1/E1 port.
Default: shutdown (which is disabled)