Configuring Call Routing - Patton electronics SmartWare R.3.20 Software Configuration Manual

Software for smartnode series
Table of Contents

Advertisement

SmartWare Software Configuration Guide
Mode: System
Step
1
node (sys)#clock-source internal
or
node (sys)#clock-source slot-number port-number
2
node (sys)#ic voice slot-number
3
node (ic-voice)[ slot-number ]#pcm law-select {
aLaw | uLaw }
Configure: General CS settings
The following example configures the general CS parameters
node>enable
node#configure
node(cfg)#system
node(sys)#clock-source 1 0
node(sys)#ic voice 1
node(ic-voice)[1]#pcm law-select aLaw
node(ic-voice)[1]#exit
Configuring call routing
Calls through a SmartNode can be routed according to a set of routing criteria. The entity that manages call
routing is called the call router. Calls are routed from one CS interface to another. The call router determines
the destination interface for every incoming call. It supports complex call routing and call property manipula-
tion (e.g. number manipulation) functions. See chapter 33,
Call routing occurs in the context CS element between several CS interfaces. Accordingly, a CS context and
two or more CS interfaces must be created.

Configuring call routing

Command
26 • CS context overview
Generates the reference clock internally
or specifies a specific port to receive the
reference clock.
Changes to ic_voice mode.
Selects the PCM aLaw for Europe or
uLaw for USA.
"Call router configuration"
Purpose
on page 381.
305