SmartWare Software Configuration Guide
Class
Protocol Error
ie-does-not-exist
(Cont.)
invalid-ie-contents
recovery-on-timer-
expiry
protocol-error
interworking
Interworking
Example: Create a hunt group service
This example shows how to configure the hunt group service as shown in
node(cfg)#context cs
node(ctx-cs)[switch]#service hunt-group HUNT-BRI
node(func)[HUNT-BRI]#cyclic
node(func)[HUNT-BRI]#timeout 6
node(func)[HUNT-BRI]#route dest-interface IF-BRI0
node(func)[HUNT-BRI]#route dest-interface IF-BRI1
node(func)[HUNT-BRI]#route dest-interface IF-BRI2
node(func)[HUNT-BRI]#route dest-interface IF-BRI3
Call router configuration task list
Table 16. Hunt group drop causes (Continued)
Default Behavior
Cause
of the Hunt
Group Service
Drop original call
Drop original call
Drop original call
Drop original call
Drop original call
33 • Call router configuration
Description
The remote equipment receives a message
that includes information elements or call
properties that are not recognized.
The remote equipment receives a message
that includes invalid information in the
information element or call property.
Your call was not completed, probably
because an error occurred.
An unspecified protocol error with no
other standard cause occurred.
An event occurs, but the network does not
provide causes for the action it takes. The
precise problem is unknown.
figure 61
on page 423.