09:13:55 FXS > [0 1] Set state to 'Ringing'
means that the binding of the port to the context CS interface is correct, and your phone should now be
ringing.
If the phone does not start to ring, revise the binding of the port to the context CS interface, and the con-
nectors of the POTS line.
09:14:02 CFXS > [EP PHONE] Change state to CONNECTED.
accepted the call. The state of the CS interface goes to CONNECTED. The call is now established.

Debugging H.323 Signaling

Overview: H.323 debug monitors
unit #debug gateway h323 signaling
unit #debug gateway h323 error
unit #debug gateway h323 datapath
unit #show gateway h323 status
unit #show gateway h323 call name
[detail detail ]
unit #show call-control provider name
[detail detail ]
S
ee also section
"Troubleshooting"
than 40 debug monitors, such as q931, ras, or signaling. For a list of all available debug monitors, refer to the
CLI online help.

Verify an incoming call

Make sure an incoming call is entering correctly context CS. In this example, a VoIP gateway or VoIP phone
on the network makes a call to your unit using a gatekeeper. The debug output below shows a normal (work-
ing) call setup sequence
unit#enable
unit#configure
unit(cfg)#debug gateway h323 error
unit(cfg)#debug gateway h323 signaling
unit#debug gateway h323 ras
unit(cfg)#show gateway h323 status
Debugging call signaling
Command
on page 489 for further informations on debugging H.323. There are more
: The port begins to ring on the analog line. This
: The phone went off-hook and thus
Prints all signaling operations on H.323 interfaces.
General purpose error monitor of H.323. Always
enable this when debugging H.323.
Prints operations on the H.323 part of the voice
data path. Use this monitor if you experience prob-
lems in the data path (no speech connectivity,
speech only in one direction). This monitor is not
needed to debug signaling.
Shows the state of the H.323 gateway. Among
others: enabled/disabled, RAS registration state.
Shows all calls ongoing on the H.323 interface on
context CS with name name.
Shows the status of an H.323 interface in context
CS (call control part of H.323 signaling). Shown
are all calls currently ongoing on the interface,
with their call states, signaling peers and voice
data path parameters.
name is the name of the H.323 interface. Use