Configuring The Hardware Port Protocol - Patton electronics SmartWare R.3.20 Software Configuration Manual

Software for smartnode series
Table of Contents

Advertisement

SmartWare Software Configuration Guide
node(prt-ser)[0/0]#encapsulation framerelay
node(prt-ser)[0/0]#show port serial
Serial Interface Configuration
------------------------------
Port
State
Hardware Port
Transmit Edge
Port Type
CRC Type
Max Frame Length: 2048
Recv Threshold
Encapsulation
Configuring the hardware port protocol
Note
Only available on certain devices.
Before using the serial interface the hardware port protocol has to be specified. There are two command
options available to select the suitable hardware port protocol:
v35 for V.35 protocol to be used
x21 for X.21 protocol to be used
Mode: Administrator execution
Step
node (cfg)#port serial slot port
1
node (prt-ser)[ slot/port ]#hardware-port {v35 | x21} Sets the hardware port protocol
2
node (prt-ser)[ slot/port ]#show port serial
3
Example: Configuring the hardware port protocol
The following example enables X.21 as hardware port protocol for the serial interface on slot 0 and port 0.
Check that Hardware Port is set to X.21 in the command output of
node(cfg)#port serial 0 0
node(prt-ser)[0/0]#hardware-port x21
node(prt-ser)[0/0]#show port serial
Serial Interface Configuration
------------------------------
Port
State
Hardware Port
Transmit Edge
Port Type
CRC Type
Max Frame Length: 2048
Serial port configuration task list
: serial 0 0 0
: CLOSED
: V.35
: normal
: DTE
: CRC-16
: 1
: framerelay
Command
: serial 0 0 0
: CLOSED
: X.21
: normal
: DTE
: CRC-16
14 • Serial port configuration
Purpose
Selects the serial interface on slot and port
Displays the serial interface configuration
.
show port serial