Patton electronics SmartWare R.3.20 Software Configuration Manual page 545

Software for smartnode series
Table of Contents

Advertisement

SmartWare Software Configuration Guide
01:00:10 H323 > [EP h323-00c07230]
01:00:10 H323 > [EP h323-00c07230]
01:00:10 H323 > [EP h323-00c07230]
allowed
01:00:10 H323 > [EP h323-00c07230]
not screened
01:00:10 H323 > [EP h323-00c07230]
01:00:10 H323 > [EP h323-00c07230]
01:00:10 H323 > [EP h323-00c07230]
01:00:10 H323 > [EP h323-00c07230] Set state to TERMINAL TRYING
01:00:10 H323 > [EP h323-00c07230] State: TERMINAL TRYING, Call Event: PEER CON-
NECTED
01:00:10 H323 > [EP h323-00c07230] State: TERMINAL TRYING, Call Event: PROGRESS
01:00:10 HRAS > Stack: Received Admission Confirm
01:00:10 H323 > [EP h323-00c07230] Stack: State: DIALTONE
01:00:10 H323 > [EP h323-00c07230] Call-ID is
0213:4d8d:13ba:1db8:2eef:0030:2b00:1e0e
01:00:11 H323 > [EP h323-00c07230] Stack: Received Incomplete-Address Indication
01:00:11 H323 > [EP h323-00c07230] Stack: State: RINGBACK
01:00:11 H323 > [EP h323-00c07230] Stack: Received ALERTING
01:00:11 H323 > [EP h323-00c07230]
01:00:11 H323 > [EP h323-00c07230] State: TERMINAL TRYING, Call Event: TERMINAL
ALERTING
01:00:11 H323 > [EP h323-00c07230] Set state to TERMINAL ALERTING
01:00:14 H323 > [EP h323-00c07230] Stack: State: CONNECTED (CALL-SETUP)
01:00:14 H323 > [EP h323-00c07230] State: TERMINAL ALERTING, Call Event: TERMINAL
CONNECTED
01:00:14 H323 > [EP h323-00c07230] Set state to CONNECTED
01:00:14 H323 > [EP h323-00c07230] Stack: Send STATUS INQUIRY
01:00:14 H323 > [EP h323-00c07230] Stack: Opening the H.245 control-channel
01:00:14 H323 > [EP h323-00c07230] State: CONNECTED, Call Event: PROGRESS
01:00:14 H323 > [EP h323-00c07230] Stack: Received STATUS. Audit successful
01:00:14 H323 > [EP h323-00c07230] Channel State: IDLE, Channel Event: CONTROL-UP
01:00:14 H323 > [EP h323-00c07230] Set channel state to OPENING
01:00:14 H323 > [EP h323-00c07230] State: CONNECTED, Call Event: PROGRESS
01:00:14 H323 > [EP h323-00c07230] Stack: State: CONNECTED (CALL)
01:00:14 H323 > [EP h323-00c07230] Stack: New Incoming Logical Channel: 00bccd68
01:00:14 H323 > [EP h323-00c07230] Channel State: OPENING, Channel Event: MODE-UP
01:00:14 H323 > [EP h323-00c07230] Set channel state to UP
Explanation:
First the state of the gateway is checked. The state is UP, and the RAS engine is REGISTERED, which
is OK.
The line
01:00:10 H323 > [EP h323-00c07230] Stack: Allocated new call: 0x00be5968
that there is a new call incoming from H.323. This means that transport layer is OK. If there is no debug
output at all, try to use
The line
01:00:10
show the calling and called party properties. In the present case, the called party number is 60.
00:29:03 HRAS > Stack: Received Admission Confirm
H.323 network with the given call parameters. If you can't see any H.323 SETUP message on the net, or if
Debugging call signaling
debug gateway h323 tpktchan
H323 > [EP h323-00c07230] Destination Address: TEL:60,60
Destination Address:
Source Address:
Presentation Indicator:
Screening Indicator:
Information Transfer Capability: Speech
Display:
User-User:
Progress Indicator: (none)
, which monitors all H.323 socket TCP traffic.
says that the gatekeeper allowed us to dial to
42 • VoIP debugging
TEL:60,60
TEL:50,50
Presentation
User provided,
50
tells
and below
545

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartware release 3.20

Table of Contents