304
C
11: D
HAPTER
IAL
P
LAN
Table 59 Explanation of Entries in
Field
Table Create 1 Internal Extensions
TableEntry Create 1
TableEntry Create 1 45
V82 (Digits column)
Min (5) Max (5)
Class (WAN)
Priority (0)
Route (532)
DestinationRoute Create 532 Atlanta VPIM Connection
DestinationRouteEntry Create 532
DestinationRouteOperation Create 532
Figure 19
Purpose
This command is present in all default dial plans. It
is included here as a reference point for
subsequent commands.
45
V82
5 5 WAN
This portion of the command creates entry 45 in
dial plan table 1 (the Internal Extensions table). The
choice of 45 as the entry number depends on how
many entries exist in table 1. This example assumes
that the highest number assigned to a previously
existing entry was 44.
The required upper case letter V indicates that this
is a VPIM connection. The number 82 indicates
that telephone users must dial 82 to access the
VPIM connection and then dial the extension they
want to reach.
You can select any number of digits for a site
code. The selected number must not conflict with
other dial plan entries. This example assumes that
82 is not used in any other way in the dial plan.
NOTE: Long digit sequences can a create an
opportunity for dialing errors.
Indicates that the total digit sequence the
telephone user dials is 5 digits. The first two digits
are the site code (82 in this example) and the
remaining 3 digits are the destination extension.
Indicates that this call is classified as WAN. All
VPIM calls have this classification.
This field is unused by the dial plan; the default
value is zero (0).
In this example, the VPIM connection to the other
NBX system uses route 532. The route number
must be unique in the dial plan and in the range of
1–32768.
This command creates route number 532 and
names it Atlanta VPIM Connection.
1 *0003
This command (mandatory for all VPIM routes)
assigns route 532 to the extension list *0003.
1
0 532
1 stripLead 3