Nortel DMS-100 Manual page 88

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Performing a warm restart
At your current location
1
Determine if you can use a MAP terminal to execute the restart.
If you
can use a MAP terminal
cannot use a MAP terminal
At the MAP terminal
2
To access the CI level of the MAP display, type
>QUIT ALL
and press the Enter key.
3
To restart the switch, type
>RESTART
WARM ACTIVE
and press the Enter key.
Example of a MAP response:
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Performing a warm restart
WARNING
Contact the next level of support
Do not attempt this procedure before you contact the next
level of support.
WARNING
Loss of service
Processed calls that do not reach the talking state disconnect
during a warm restart.
WARNING
Extended service interruption
Execute the restart from a MAP terminal. According to the
severity of the problem, MAP terminals can be out of service.
If a MAP terminal is not available, perform the restart from
the CM reset terminals.
Do
step 2
step 6
2-41
(continued)