5-154 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one MS plane
13
14
297-8021-545 Standard 14.02 May 2001
b
Press down and release the switch on the faceplate of the NT9X31 power
converter in slot 1F.
c
Go to step 14.
Power down the slave MS as follows:
a
Press down and release the switch on the faceplate of the NT9X30 power
converter in slot 36F.
b
Press down and release the switch on the faceplate of the NT9X30 power
converter in slot 33F.
Return to the procedure Emergency power conservation—Shutdown in this
document. Proceed when the step-action procedure directs you to go.