Emergency shutdown of one junctored network plane
Emergency shutdown of one junctored network plane
At the MAP terminal
1
To access the NET level of the MAP display, type
>MAPCI;MTC;NET
and press the Enter key.
Example of a MAP response:
Net
Plane
01234
0
....
1
....
JNET:
2
Select a network plane pair to power down.
3
To manually busy the network module that you will power down, type
>BSY
and press the Enter key.
where
Emergency power conservation recovery procedures
WARNING
Potential service interruption or extended outage
Nortel recommends that you contact the Emergency
Technical Assistance Services (ETAS) or next level of
support before you perform this procedure.
WARNING
Potential loss of service or extended outage
Perform this procedure to conserve emergency backup
power. Do not use this procedure or sections of this
procedure for equipment maintenance purposes.
11111
11111
56789
01234
plane_no
pair_no
plane_no
is the network plane number (0 to 1)
pair_no
is the network plane pair number (0 to 31)
DMS-100 Family NA100 Recovery Procedures LET0015 and up