2-12 System level recovery procedures
Booting a DMS switch
31
32
At the CM reset terminal for the ACTIVE CPU
33
34
35
297-8021-545 Standard 14.02 May 2001
(continued)
image file
Example input:
>\BOOT
SLM0
RTIF response:
BOOT Please confirm: (YES/NO)
To confirm the command, type
>YES
and press the Enter key.
RTIF response:
BOOT INITIATED
To release the jam on the inactive CPU, type
>\RELEASE
JAM
and press the Enter key.
RTIF response:
JAM RELEASE DONE
To override the active CPU, type
>\OVERRIDE
and press the Enter key.
RTIF response:
TEMP. RESET/JAM ENABLE
To jam the active CPU, type
>\JAM
and press the Enter key.
RTIF response:
Please confirm: (YES/NO)
Note: An active CPU jam causes a switch of activity. A jam causes the
active CPU to become inactive.
To confirm the command, type
>YES
and press the Enter key.
RTIF response: