Nortel DMS-100 Manual page 218

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Recovery procedures for individual devices and services
30
Force the HSLR to busy by typing
>BSY
FORCE
and pressing the Enter key.
31
Return the HSLR to service by typing
>RTS
and pressing the Enter key.
If the RTS command
passed
failed
anything else
32
Force the HSLR to busy by typing
>BSY
FORCE
and pressing the Enter key.
33
Reset the HSLR by typing
>PMRESET
and pressing the Enter key.
If the PMRESET command
passed, and the HSLR is ISTb
or InSv
passed, and the HSLR is ManB
failed, and the HSLR is ManB
34
Reload the HSLR by typing
>LOADPM
and pressing the Enter key.
If the LOADPM command
passed
failed
35
Return the HSLR to service by typing
>RTS
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Checking for call completion
Do
step 36
step 32
step 50
Do
step 36
step 35
step 34
Do
step 35
step 50
4-11
(continued)