2-108 System level recovery procedures
Recovering from a dead system in a SuperNode SE switch
126
127
128
129
130
297-8021-545 Standard 14.02 May 2001
When power returns to all LPPs or ELPPs, continue this procedure at step
126.
To access the SRSTATUS level of the MAP display, type
>SRSTATUS
and press the Enter key.
Example of a MAP display:
SRSTATUS
OVERALL STATUS Pend:
0
Quit
VIEW: SYSTEM
2
View_
Pend InPrg
3
List_ MS
0
4
NET
0
5
SER1
0
6
SER2
1
7
SER3
11
8
9
SRSTATUS:
From the MAP display, determine the recovery status of the Series III PMs.
Note: Series III PM recovery status appears on the right side of the word
SER3 in the MAP display. Recovery status can be pending, in progress,
complete, or failed.
If the number of Series III PMs
that failed recovery
is zero
is other than zero
Determine if a link peripheral processor (LPP) or enhanced link peripheral
processor (ELPP) or the SCC contains the Series III PMs that failed recovery.
If the Series III PMs that failed
recovery are in
an LPP or ELPP
the SCC
Perform the procedure Recovering SuperNode SE application specific units
in this document to manually recover the PMs.
Complete the procedure and return to this point. Go to step 131.
Perform the procedure Recovering link peripheral processors in this
document to manually recover the PMs.
Complete the procedure and return to this point.
18%
InProg: 9%
Comp
Fail
0
2
0
IOD
0
6
0
Other 21
1
6
0
1
60
1
8
30
1
Do
step 131
step 128
Do
step 130
step 129
(continued)
Comp: 70%
Fail: 3%
11:52:34
Pend
InPrg
Comp
Fail
5
5
30
3
13
2
3